I’m your trusted partner for a reliable Filter differential pressure switch that keeps filtration lines running at peak efficiency. As a High-Quality Supplier, I know how crucial accurate pressure signals are for process control and plant uptime. This switch monitors the differential across your filters and triggers alarms or automated backwash when setpoints are reached, helping you minimize waste and unexpected downtime. Built with a robust diaphragm, corrosion‑resistant housing, and easy wiring, it fits standard piping and electrical cabinets without fuss. Adjustable setpoints, clear electrical contacts, and a compact form factor make installation and maintenance simple for field teams. Whether you need normally open or normally closed operation, this unit scales across small to medium systems with reliable repeatability. If you’re looking for a durable, precise, cost‑effective sensor for critical filtration, I’ve got you covered. Send me your spec, I’ll tailor the offer with datasheet, lead times, and competitive pricing.

Hot Selling Product

Filter differential pressure switch Trusted by Pros Leads the Global Market

Filter differential pressure switches trusted by professionals worldwide deliver precise, reliable monitoring for HVAC, filtration, pharmaceutical, power and industrial applications. Engineered for accuracy and durability, they offer adjustable setpoints, clear switching logic, multiple output options and rugged enclosures that withstand harsh environments. By enabling timely maintenance actions, these switches reduce downtime, extend filter life, improve energy efficiency and help facilities meet regulatory standards. Global buyers benefit from consistent manufacturing quality that meets international standards, flexible customization, competitive lead times and responsive technical support. Whether you need OEM volumes, tailored calibration or rapid shipment to project sites, partnering with a proven global leader ensures predictable supply, risk mitigation and measurable lifecycle savings for critical filtration systems.

{ Filter differential pressure switch Trusted by Pros Leads the Global Market}
Model Setpoint Range (Pa) Hysteresis (Pa) Contact Rating Wetted Materials Connection Type Response Time (ms) Ambient Temp Range (°C) Approvals
DPX-100 50 – 150 5 – 10 SPDT; 5 A @ 250 VAC Stainless Steel 316L wetted parts; FPM diaphragm G 1/4 in; 1/2 NPT optional ≤ 5 -20 to 70 CE, UL Listed, RoHS
DPX-150 80 – 400 6 – 12 SPDT; 5 A @ 250 VAC 316L stainless steel; Viton O-rings G 1/4 in ≤ 6 -20 to 70 CE, UL Listed
DPX-200 100 – 600 6 – 14 SPDT; 5 A @ 250 VAC 316L; PTFE diaphragm G 1/4 in; 1/2 NPT option ≤ 6 -25 to 75 CE, UL Listed, RoHS
DPX-300 200 – 1000 12 – 20 SPDT; 4 A @ 250 VAC 316L; Fluorinated elastomer O-rings G 3/8 in ≤ 8 -20 to 75 CE, UL Listed, ATEX
DPX-500 400 – 1600 20 – 40 SPDT; 4 A @ 250 VAC 316L; PTFE G 1/2 in ≤ 12 -20 to 65 CE, UL Listed, RoHS, ATEX

Related Products

Filter differential pressure switch Service Factory-Direct Excellence

Operating Environments vs Average Differential Pressure and Activation Rate

This chart compares two complementary metrics across representative operating environments: average differential pressure (in mbar) and average switch activations normalized to 1000 operational hours. Differential pressure provides a steady-state indication of filter resistance or system demand, while activation frequency highlights transient events, fouling variability, or setpoint sensitivity. Clean Room conditions show very low average pressure and modest activations, reflecting controlled airflow and frequent but predictable cycling. Industrial Dusty environments display both high pressure and high activation counts, indicating heavy particulate loading that elevates resistance and provokes repeated switch trips. Outdoor Humid conditions produce moderate pressure with intermediate activations, consistent with periodic moisture-driven fluctuations. Marine Saline environments register mid-range pressure but relatively high activations, suggesting corrosive deposits or salt-induced variability that trigger frequent trips despite only moderate steady pressure. High Temperature Processing stands out with the highest differential pressure and activation count, implying increased viscosity or high particulate loads combined with unstable flow conditions. Low Temperature Storage exhibits low pressure and low activation frequency, reflecting stable, low-bioburden conditions. Practically, combining these two metrics helps prioritize maintenance and tune switch setpoints: targets with both elevated mbar and high activation rates should be serviced first, while environments with moderate pressure but high activations may require calibration, transient mitigation, or environmental controls. Using this dual-metric approach supports predictive maintenance, reduces nuisance trips, and prolongs sensor and filter life.