Two-Color Level Gauge’s Clear Vision: The B69H-32-W Mica-Glass Gasket Assembly

Two-Color Level Gauge’s Clear Vision: The B69H-32-W Mica-Glass Gasket Assembly

At a power plant boiler site, noise meets steam. The operator stands at the two-color level gauge, needing only a glance at the red-and-green display to know the water level—steam phase is red, liquid phase is green, the boundary sharp and clear. This direct, reliable reading relies entirely on the stable performance of the B69H-32-W Mica-Glass Gasket Assembly. Ordinary glass shatters or blurs fast under the boiler’s 10MPa+ pressure and 300°C+ heat, but this mica-glass unit holds the line long-term. How does it maintain clear, accurate readings through the temperature shock of startups and the erosion of steam/water? The answer is hidden in every detail of material choice, structural design, and operating condition compatibility.

 


I. Materials: A Hardcore Foundation for High Heat and Pressure

The core of the B69H-32-W Mica-Glass Gasket assembly is a mica-glass composite, not just simple glass. This combination is custom-built for extreme boiler conditions, solving the three main problems of ordinary glass: fear of high heat, high pressure, and shock.

 

Mica Core: The Natural Barrier Against Thermal Shock

The assembly’s middle layer is high-purity white mica sheeting, critical for resisting temperature shifts. During cold startups, water temperature rapidly climbs from room temperature to saturation, with glass surface changes exceeding 200°C. During hot shutdowns, it plunges from high temp back to ambient. Ordinary glass has uneven thermal expansion, making it prone to cracking under rapid temperature change due to internal stress. Mica’s layered crystal structure effectively distributes the stress from temperature changes; even with instant fluctuations of 150°C, cracks won’t appear.

One plant once mistakenly installed a plain glass unit. The glass shattered just 20 minutes into boiler startup; leaking steam and water nearly caused a serious safety incident. After switching to the B69H-32-W, the unit went through five consecutive startup/shutdown cycles with the surface remaining flawless and the reading clear. This thermal shock resistance is why the local level gauge doesn’t go blind during critical startup/shutdown phases.

 

High-Strength Glass Layers: The Protective Coat Against Abrasion

High-strength borosilicate glass is bonded to both sides of the mica core, forming a mica + glass sandwich. During boiler operation, the steam-water mixture constantly washes over the gauge face. Especially in high-parameter boilers, the flow speed can hit 3m/s. Ordinary glass quickly develops fine scratches, blurring the reading. Borosilicate glass has a Mohs hardness of 6.5, far exceeding the hardness of impurities carried by the steam and water. This effectively resists scouring and abrasion.

This composite structure balances transparency and strength. Borosilicate glass has over 92% light transmission, perfect for the two-color gauge’s optical imaging. The mica layer, though opaque, is precision-cut and acts only as structural support, not affecting the red/green boundary display. Combined, they withstand steam-water erosion while guaranteeing visual clarity.

 


II. Structural Design: Dual Precision in Sealing and Optics

Good materials alone aren’t enough. The B69H-32-W mica glass gasket’s structure ensures the water level reading stays accurate and clear from two angles: sealing and optics.

 

Stepped Sealing: The Defense Line Against Leakage

A common cause of blurred gauge readings is steam/water leaking from the gap between the glass and the frame, creating a water film or scale on the surface. The B69H-32-W mica glass gasket uses a stepped sealing groove design. The component edges are machined into steps that precisely match the gauge frame’s sealing channel. This, combined with high-temperature graphite gaskets, forms a dual seal.

The advantage here is that higher boiler pressure results in tighter sealing. During operation, boiler pressure pushes the glass assembly firmly against the gasket, filling micro-gaps. Pressure fluctuations during startup/shutdown don’t break the seal. A subcritical boiler using this unit ran continuously for eight months with no signs of steam/water leakage on the gauge surface, avoiding reading errors caused by scale buildup.

 

Optical Flatness: Ensuring the Sharpness of the Red/Green Boundary

The two-color gauge works by light refraction and reflection: the steam phase strongly reflects red light, the liquid phase strongly refracts green light, creating a distinct red/green boundary after passing through the glass. This relies on the extremely high flatness of the glass assembly surface. Both glass faces of the B69H-32-W mica glass gasket are precision-ground, with flatness error controlled to under 0.01mm—about 1/7th the width of a human hair.

Poor flatness causes light scattering, blurring the red/green boundary and creating a transition color band that prevents the operator from determining the true water level. This unit’s high-precision flat surface ensures light travels along its intended path. Even during low-load periods with frequent water level fluctuations, the red/green boundary remains sharply defined. One plant operator noted that after replacement, they could accurately track interface shifts for level changes as small as 5mm, avoiding past mistakes caused by blurred readings.

 


III. Operating Condition Adaptability: Full-Cycle Stability from Startup to Run

Throughout the boiler cycle, startup/shutdown phases present the worst conditions, while the run phase demands long-term stability. The B69H-32-W mica glass gasket achieves full-cycle reliability through detailed design.

Startup/Shutdown: The Toughness Against Sudden Changes

During cold startup, the boiler is preheated with low-pressure steam; the glass assembly moves through low-temp to rising-temp to constant-temp. During hot shutdown, it suffers a sudden shift from high-temp to falling-temp to ambient. The B69H-32-W’s composite materials have specially matched thermal expansion coefficients, with the difference in expansion rate between mica and glass controlled to within 0.5×10⁻⁶/℃. This avoids delamination due to temperature changes.

Also, the component’s chamfered edge design (1.5mm radius) disperses stress concentrations during startup/shutdown, preventing corner cracking. One plant, with frequent startup/shutdown cycles (averaging 4 times a month), had to replace ordinary units monthly. The B69H-32-W showed no damage signs after six months of continuous use.

 

Run Phase: Endurance Against Corrosion and Scale

Boiler water contains trace salts and alkaline substances, which can cause scale buildup on the glass surface during long-term operation, impacting transparency. The B69H-32-W’s glass surface is specially coated, creating a hydrophobic, anti-scale layer that resists deposit adherence. Even if minor scaling occurs, it can be easily removed by the gauge’s own flushing device without damaging the glass surface.

Furthermore, the coating resists boiler water corrosion. At high pressure, boiler water alkalinity increases, slowly corroding ordinary glass and making the surface rough. This unit’s coating blocks direct contact between water and glass, allowing stable operation over the long term within a pH range of 8–12. Its service life can exceed 12 months—three times that of ordinary units.

 


IV. Maintenance Essentials: Simple Steps to Extend Lifespan

The B69H-32-W mica glass gasket is highly reliable, but routine maintenance still requires two points of attention to ensure reading accuracy: First, regular flushing—at least once a week using high-pressure steam to remove trace scale deposits. Second, check the seal—monthly check for signs of gasket aging; if steam/water seepage is found at the gauge edge, replace the gasket immediately to prevent corrosion of the glass assembly.

If cracks, scratches, or a blurred red/green boundary appear on the surface during maintenance, replacement is necessary immediately. Delaying replacement risks reading errors or, worse, component shattering and a safety incident. Choosing an original equipment manufacturer (OEM) standard component is crucial—non-standard components lack guaranteed flatness and material quality, increasing the risk of failure.

 


Conclusion: Select the Core Component, Guard the Water Level Safety Line

The clear, accurate reading of the two-color gauge is the first line of defense for boiler safety, and the B69H-32-W Mica-Glass Assembly is the core foundation of that defense. It uses a composite of mica and high-strength glass to withstand extreme conditions and guarantees reading precision with stepped sealing and high-accuracy flatness. From startup to operation, it provides operators with a reliable water level reference.

If your plant’s two-color gauge shows blurred readings, unclear boundaries, cracks, or leaks, do not rush to replace the entire gauge. Contact us. We supply OEM standard components and professional installation guidance to quickly restore clear and accurate water level indication. Guarding the water level safety line makes every startup and run safer and more reliable.


  • Previous:
  • Next:

  • Post time: Nov-20-2025