In a power plant, startup/shutdown of feedwater pumps, valve operations, and pressure interlocks all rely on the AVR isolated digital I/O board to transmit signals. The ISO-P2C32, a common model, has 32 independent channels, each linking to a different field device. The external circuit is an extension of these channels, and faults can be triggered by aging cables, loose connectors, or equipment shorts. In the past, with basic I/O boards, if the control system lost a signal, maintenance staff had to grab a multimeter and start tracing the cable from the I/O board terminal all the way to the field device. When dealing with complex wiring trays, this troubleshooting could take hours with no guaranteed result. The channel status diagnostic feature of the ISO-P2C32 is like installing eyes directly on the I/O board, allowing preliminary problem identification without disconnecting wires.
I. Diagnostic Core: Hardware and Algorithm Supporting the ISO-P2C32
Channel status diagnosis is not just a simple check for signal presence; it’s a complete assessment of loop integrity. The ISO-P2C32 is designed with both hardware and software algorithms to ensure accurate diagnostics. This prevents signal interference from being wrongly flagged as a fault and ensures real loop problems aren’t missed.
Hardware Isolation: Drawing the Line for Diagnostic Signals
Every channel on the AVR isolated digital I/O board ISO-P2C32 has its own independent photoelectric isolation module. This isolation not only blocks electromagnetic interference from the field but also ensures the diagnostic circuit and the signal transmission circuit don’t affect each other. During diagnosis, the I/O board sends a weak detection current into the external loop. This current is separate from the normal signal current; it’s too weak to trigger the field device but accurately reports the circuit’s open or closed status.
On typical I/O boards, channels share power and detection circuits, meaning a short in one channel can take out the entire board’s diagnostic capability. The ISO-P2C32 gives each channel its exclusive diagnostic power module. Even if one channel has a severe short circuit, only that channel’s diagnosis is affected. All other channels continue monitoring normally. This design makes the diagnosis much more reliable; a local fault won’t cause total blindness.
Smart Algorithm: The Logic for Distinguishing Fault Types
The ISO-P2C32′s diagnostic algorithm can identify three key states: Normal, Open Circuit, and Short Circuit (短路). It judges by monitoring changes in loop current: a normal loop has a stable current path, and the detection current returns as expected; when the circuit is open, loop resistance is infinite, and detection current is zero; when short-circuited, loop resistance approaches zero, and the detection current far exceeds the normal range.
The algorithm also includes a time-delay mechanism. Instantaneous poor contacts sometimes happen in the plant—like a connector briefly disconnecting and reconnecting due to vibration—and these shouldn’t trigger an alarm. The ISO-P2C32 continuously monitors for 300 milliseconds. A fault is only confirmed and reported if the condition persists beyond this time, avoiding false alarms caused by transient interference. If your plant has had issues with equipment frequently starting and stopping due to I/O board false alarms, the ISO-P2C32′s design can effectively solve it. Contact us for adaptation advice.
II. Real-World Performance: Quick Identification of Open and Short Circuits
For different loop failures, the ISO-P2C32 provides specific diagnostic feedback, presented both by indicator lights and software interface. This allows maintenance staff, whether at the cabinet or in the control room, to quickly get the information.
Open Circuit (Break): Pinpointing the Break Point
When an external cable breaks due to aging or a connector loosens, the corresponding channel’s red diagnostic light on the ISO-P2C32 stays on. Simultaneously, the control system’s monitoring software displays fault code E01 and the message Open Circuit. When staff see this, they skip the full system check and focus only on the cable connectors and vulnerable sections corresponding to that channel.
For example, if the feedwater pump start/stop control loop is open, a standard I/O board only shows signal lost, leading staff to possibly check the pump itself first. The ISO-P2C32 directly points to Open Circuit. Staff go straight to the cable tray for that channel, and often find the loose connector in 10 minutes, improving troubleshooting efficiency by over 80% compared to the traditional method.
Short Circuit: Timely Alarm Prevents Bigger Damage
An external short circuit is more dangerous than an open circuit; it can burn out the I/O board or field equipment. When the ISO-P2C32 detects a short circuit, in addition to the diagnostic light flashing and the software displaying fault code E02, it triggers a hardware protection mechanism. It immediately cuts off the signal output of that channel and limits the detection current, preventing the fault from escalating.
One power plant had a valve control loop short circuit. The ISO-P2C32 triggered protection and alarming within 50 milliseconds. When staff arrived, they found the short was caused by damaged cable insulation. Because the I/O board cut the output so fast, the valve controller in the field was not burned out, and operation was restored just by replacing the cable. A standard I/O board would likely have resulted in damage to both the board and the controller, multiplying the loss.
III. Maintenance Upgrade: From Fixing Reactively to Preventing Proactively
The ISO-P2C32′s channel diagnosis capability not only fixes existing faults quickly but also enables preventive maintenance. This shifts the system from repairing after failure to catching risks early, which is essential for boosting control system stability.
Trend Monitoring: Catching Sub-Healthy Circuits
Beyond simple fault identification, the ISO-P2C32 also records the circuit resistance change for every channel. Under normal conditions, circuit resistance is stable. If the resistance gradually increases, it suggests the cable might be aging or the connector is oxidizing—these are precursors to an open circuit fault. By checking the resistance change trend in the monitoring software, maintenance staff can replace the cable or fix the connector before a fault occurs, stopping the risk while it’s still small.
This trend monitoring is especially useful for equipment in remote areas. Desulfurization and denitrification systems in power plants are often in isolated spots where cable maintenance is difficult. The ISO-P2C32′s trend data lets staff monitor circuit status without doing physical field patrols, reducing unnecessary field work.
Data Logging: Optimizing Maintenance Strategy
The ISO-P2C32 automatically stores fault records for the past 3 months, including the faulty channel, fault type, time of occurrence, and duration. By analyzing this data, staff can identify high-failure channels and equipment, allowing them to optimize maintenance plans. For example, if one channel frequently has bad contact, vibration in that area might be too high, requiring a more robust terminal block. If multiple channels in one cable tray fail, the humidity inside the tray might be too high, requiring a dehumidifier.
This data also provides a basis for equipment selection. If analysis shows cable quality is the problem, the next purchase can prioritize more aging-resistant models. If the issue is the equipment interface, discussions with the manufacturer can lead to optimization, reducing faults at the source.
Conclusion: Choose the Right I/O Board for More Efficient Maintenance
The channel status diagnostic feature of the AVR Isolated Digital I/O Board ISO-P2C32 might seem like a small detail, but it solves a huge pain point in power plant control system maintenance. It cuts troubleshooting time from hours down to minutes, turning reactive repair into proactive prevention. This reduces downtime losses and lowers the workload for maintenance staff. With power plants demanding increasingly stable control systems, this type of I/O board—which handles both signal transmission and fault diagnosis—has become a key component for improving system maintainability.
If your plant’s control system is still struggling with hard-to-find I/O board faults and low maintenance efficiency, or if you need to equip a new system with an AVR isolated digital I/O board, contact us. We supply the genuine ISO-P2C32, complete with professional installation and debugging services. We can also optimize the diagnostic settings based on your system parameters, ensuring no channel fault is hidden, and making your control system run more stably and maintenance more worry-free.
E-mail: sales@yoyik.com
Tel: +86-838-2226655
Whatsapp: +86-13618105229
Yoyik offers various types of power plants spare parts for steam turbines, generators, boilers as below:
Eddy Current Sensor PR6422/104-121
Pressure Switch 821097
Blower (fan)for forced air cooling of dry type power transformers GFD580-150
linear lvdt TDZ-1-13
TSI Card 3500/45
speed meter MCS-II
intelligence Hand Operator NPDF-Q200
Acoustic sensor DZXL-V1
High Speed Bus Power Transfer System MFC2000-3A
intelligence Hand Operator NPDF-Q21F0
Vibration Sensor MT-3
Heat Exapansion Sensor TD-2-02 (0-35 mm)
Main Control Board ST
Eddy current sensor preamplifier DS821.od110
intelligence Hand Operator NPDF-Q211F4
Electric actuator SND-Z30-24S
Fan for forced air cooling of dry type power transformers GFD680-200
Eddy Current Sensor PR6423/002-120
intelligence Hand Operator NPDF-D110D5
speed meter HZS-04-X
linear transducer types LVDT TDZ-1-H 0-200
Zero speed probe with switch JYB/RDC-B
RELAY PROTEKSI IN ST571H-400-VM
RESISTANCE TEMPERATURE DETECTOR WZRK-105/Φ5/L=400mm
Vibration Probe TM0182-A90-B00-C00
PRESS. SWITCH CMS
stainless steel thermocouple WRNK2-346
Differential Pressure Switch 2 RC778NZ090ZYA
Post time: Dec-11-2025