Linear displacement transducer sensor ODM Factory

I am a design specialist at an ODM Factory, and I want to present our linear displacement transducer sensor that unlocks precise motion control for your production lines. This device delivers reliable position feedback with high resolution, tight repeatability, and low drift across temperature—ideal for CNC machines, robotics, and automated assembly. We support multiple output formats including 0-10V, 4-20mA, SSI, and CANopen, plus optional digital interfaces. The rugged housing is IP67 rated for industrial environments, with long service life and easy installation. As an ODM partner, we can tailor length, connectors, and cable to your needs, while offering competitive factory pricing and short NPI cycles. We stand behind our quality with thorough testing and documentation. If you’re seeking a scalable supply chain, our factory can meet your ODM demands and help you accelerate time-to-market with dependable linear displacement transducer sensor solutions.

Hot Selling Product

linear displacement transducer sensor Manufacturer Industry Giant

As a global leader in linear displacement transducer sensors, we deliver precision measurement solutions that power automation across industries. From standard components to integrated systems, our products are engineered for accuracy, durability, and long-term stability in demanding environments. Whether for robotics, CNC tooling, or process automation, robust design and scalable production ensure reliable performance for international procurement, with consistent quality and ongoing lifecycle support. When evaluating a supplier, buyers should look for high accuracy and repeatability, suitable resolution, and environmental resilience (temperature range, IP rating). Flexible interfaces such as analog (0-10 V, 4-20 mA) and digital protocols, plus a choice of stroke lengths and mounting options, are essential. Our range includes traditional LVDT-like sensors and non-contact magnetostrictive designs, with customizable cables and assemblies. Global service features calibration, traceability, factory acceptance testing, and reliable lead times. A partner delivering standardized products with tailored modifications helps reduce risk and accelerate multi-site deployments.

{ linear displacement transducer sensor Manufacturer Industry Giant}
Model (Type) Measurement Range Resolution Accuracy Repeatability Output Type Supply Voltage Bandwidth / Response Protection / Temp Notes
LDT-01 (Magnetostrictive) 0 – 2000 mm 0.001 mm ±0.02% FS ±0.005 mm Digital (SSI/RS485), 0–10 V 10 – 30 VDC DC – 10 kHz IP67; -40 – 85°C Non-contact, long stroke durability, high repeatability
LDT-02 (LVDT) 0 – 100 mm 0.001 mm ±0.05% FS ±0.01 mm AC differential (requires conditioner) AC excitation (external) DC – 5 kHz IP65; -55 – 125°C Contactless core; excellent thermal stability
LDT-03 (Potentiometric) 0 – 500 mm 0.01 mm ±0.10% FS ±0.02 mm 0–10 V / Potentiometer wiper 5 – 24 VDC DC – 500 Hz IP54; -20 – 80°C Simple, cost-effective; moving-contact design
LDT-04 (Optical Encoder) 0 – 1200 mm 0.0005 mm ±0.005% FS ±0.0005 mm Digital (TTL/RS422) 5 VDC DC – 100 kHz IP64; 0 – 70°C High resolution for precision positioning; requires clean environment
LDT-05 (Magnetic Hall) 0 – 300 mm 0.01 mm ±0.20% FS ±0.05 mm 4–20 mA, 0–10 V 12 – 30 VDC DC – 2 kHz IP68; -40 – 85°C Robust in harsh/ wet environments; contactless operation
LDT-06 (Capacitive) 0 – 5 mm 0.0001 mm ±0.01% FS ±0.0002 mm 0–10 V / Digital 12 – 24 VDC DC – 20 kHz IP65; -20 – 85°C Very high resolution for short-range, non-contact gap measurement
Legend: FS = Full Scale; bandwidth values indicate typical usable frequency range; protection rating indicates enclosure rating for sensor body.

Related Products

linear displacement transducer sensor Global Reach From Concept to Delivery

Stroke Range vs Average Linearity Error (%)

This chart, titled "Stroke Range vs Average Linearity Error (%)", compares representative average linearity error across five common stroke ranges for linear displacement transducer sensors. Each bar shows a typical full-scale linearity error (expressed as a percentage) observed in production-grade devices under controlled laboratory conditions: 0–10 mm (0.10%), 10–50 mm (0.20%), 50–100 mm (0.35%), 100–200 mm (0.60%), and 200–500 mm (1.20%). The visible trend reflects a common engineering trade-off: shorter stroke transducers typically deliver lower linearity error due to shorter sensing elements, tighter mechanical tolerances, and reduced cumulative alignment deviations, while longer strokes accumulate more mechanical variation, greater susceptibility to hysteresis, and amplified electrical noise resulting in higher observed error. Interpreting these averaged values aids system designers in selecting the optimal sensor family for accuracy, size, and cost constraints. For high-precision needs, choosing a shorter stroke unit or segmenting long ranges into multiple sensors can reduce effective error. For long-range measurements, techniques such as enhanced signal conditioning, temperature compensation, higher-resolution ADCs, segmented sensing architectures, and improved mechanical guidance are essential to preserve measurement fidelity. Additionally, sampling strategy and filtering affect apparent accuracy: higher sampling rates with proper anti-aliasing and oversampling can improve effective resolution at the expense of processing complexity. These plotted numbers are intended as comparative baselines rather than guaranteed specifications. Real-world performance depends on application dynamics, mounting quality, environmental exposure, and calibration procedures. Final selection should include targeted validation—dynamic tests, repeatability checks, and long-term stability studies—plus iterative calibration and compensation to meet the required system-level accuracy.

Top Selling Products