page_banner

Precautions for using generator slot sealant HEC892

Precautions for using generator slot sealant HEC892

Generator slot Sealant HEC892 is a special sealant designed specifically for sealing generator end covers. It is mainly used for hydrogen cooled generators, with the purpose of sealing the hydrogen inside the generator to ensure that the hydrogen does not leak out, thereby ensuring the safe operation of the power plant. HEC892 is a single component sealant with high-quality sealing performance, especially suitable for conditions with high requirements for smooth and flat sealing surfaces and pressure.

HDJ892 (1)

Slot Sealant HEC892 is not only suitable for sealing hydrogen gas, but also for sealing metal joints, such as steam turbines, gas turbines, compressors, pumps, casings, flange joints, etc. In addition, this product may also be used in other industrial applications that require sealing of hydrogen gas.

Generator hydrogen sealing slot sealant HDJ892 (1)

When using slot Sealant HEC892, the following precautions should be taken:

1. Preparation before use: Before using HEC892, ensure that the smoothness and pressure requirements of the confidential cover (docking) are high. For hydrogen sealing, it is also necessary to ensure the cleanliness of the sealing area to avoid impurities affecting the sealing effect.

2. Application method: When applying HEC892, it is necessary to ensure uniform application and avoid bubbles and voids. Especially under high temperature conditions, it is important to ensure that the glue is evenly applied to ensure the sealing effect.

3. Curing time: slot Sealant HEC892 requires a certain amount of time to cure after application. Generally, curing can be completed after 24-48 hours. During the curing process, the adhesive should be avoided from coming into contact with water, dust, or other impurities to avoid affecting the sealing effect.

4. Check the sealing effect: After curing, the sealing area should be inspected to ensure that the sealing effect meets the requirements. If any problems are found, timely measures should be taken to repair them.

5. Regular inspection: slot Sealant HEC892 has good waterproof, aging resistance, seismic resistance, acid and alkali resistance, and high strength performance. However, in extreme environments, regular inspection and replacement are still necessary to ensure the integrity of the sealant.

Generator hydrogen sealing slot sealant HDJ892 (2)HDJ892 (2)

The generator slot Sealant HEC892 plays a crucial role in the sealing of hydrogen cooled generators. The correct use of HEC892 not only ensures that hydrogen gas inside the generator does not leak out, but also effectively prevents hydrogen leakage in other industrial occasions, ensuring the safety of equipment and personnel. Regular inspection and maintenance are also key to ensuring the performance of the sealant. Only by doing these tasks well can HEC892 achieve the best sealing effect and ensure the safe operation of the equipment.


  • Previous:
  • Next:

  • Post time: Nov-20-2023