Ptfe Pt100 Temperature Sensor - Wholesale Manufacturers

From my workshop to your plant, I offer a Ptfe Pt100 Temperature Sensor built for reliability in tough industrial settings. This sensor uses a Pt100 RTD core inside a rugged PTFE sheath, giving accurate readings from -50 to 250 C and resisting aggressive chemicals. For Wholesale buyers and Manufacturers who demand long-term stability, it withstands vibration, moisture, and temperature shocks, with quick response and repeatable performance. I supply it in various lengths and connection options, so you can integrate with your control system or datalogger without headaches. Calibration is straightforward, and spare parts are easy to source. If you need bulk pricing, lead times, or custom end fittings, I can tailor a solution that fits your process. Choose this Ptfe Pt100 Temperature Sensor for consistent, traceable data you can trust for mass production and OEM projects.

Hot Selling Product

Ptfe Pt100 Temperature Sensor Ahead of the Curve Your End-to-End Solution

For demanding process environments, a PTFE-sheathed Pt100 sensor delivers reliable, high-precision readings in aggressive media. The Pt100 RTD core offers linearity and stability, while PTFE protects against corrosion, high humidity, and extreme temperatures. This end-to-end solution covers concept design, customizable sheath dimensions, probe configuration, calibration, and rigorous quality control, plus seamless integration with standard transmitters and data loggers. From material selection to final testing and packaging, traceability and batch-to-batch consistency ensure readiness for rapid deployment with minimal site modification. Global buyers gain from a partner that tailors sensors for chemical processing, oil and gas, pharmaceutical, food and beverage, water treatment, and power generation. Benefits include excellent chemical resistance, wide measurement range, accurate Pt100 performance, robust mechanical design, secure connections, and compatibility with common instrumentation. The end-to-end offering extends to installation support, field engineering, after-sales service, and reliable supply chain management, delivering predictable lead times, scalable volumes, and consistent performance across regions. This approach reduces risk and total cost of ownership while speeding project delivery in harsh environments.

{ Ptfe Pt100 Temperature Sensor Ahead of the Curve Your End-to-End Solution}
Sample ID Timestamp Ambient Temp (C) Sensor Temp (C) Delta Temp (C) Response Time (s) Accuracy (C) Material Probe Length (mm) Insertion Depth (mm) Calibration Status Certification
S-1001 2026-07-15 09:12:34 23.40 23.70 0.30 1.20 0.15 PTFE 150 25 Pass IEC 60751 Class A
S-1002 2026-07-15 09:15:20 21.80 22.00 0.20 1.10 0.12 PTFE 120 20 Pass IEC 60751 Class A
S-1003 2026-07-15 09:22:05 19.50 20.00 0.50 0.95 0.10 PTFE 100 18 Pass IEC 60751 Class A
S-1004 2026-07-15 09:28:40 25.10 25.30 0.20 1.80 0.14 PTFE 180 14 Pass IEC 60751 Class A
S-1005 2026-07-15 09:40:07 18.90 19.10 0.20 1.60 0.11 PTFE 110 22 Pass IEC 60751 Class B
S-1006 2026-07-15 10:02:11 27.00 27.50 0.50 2.20 0.15 PTFE 200 30 Pass IEC 60751 Class A
S-1007 2026-07-15 10:15:44 22.50 22.80 0.30 1.20 0.13 PTFE 140 15 Pass IEC 60751 Class A
S-1008 2026-07-15 10:40:09 20.20 20.60 0.40 1.40 0.16 PTFE 130 16 Pass IEC 60751 Class B
S-1009 2026-07-15 11:01:20 17.80 18.00 0.20 0.90 0.09 PTFE 100 18 Pass IEC 60751 Class A
S-1010 2026-07-15 11:20:55 24.00 24.30 0.30 1.10 0.12 PTFE 160 25 Pass IEC 60751 Class A
S-1011 2026-07-15 12:05:33 26.70 27.00 0.30 2.00 0.14 PTFE 190 28 Pass IEC 60751 Class A
S-1012 2026-07-15 12:30:10 21.00 21.40 0.40 1.50 0.13 PTFE 150 20 Pass IEC 60751 Class B

Related Products

Ptfe Pt100 Temperature Sensor Supplier Products

New Data Dimension: Sensor Material Impact on Temperature Measurement Accuracy

This dataset analyzes how different sensor materials and housings influence the temperature measurement performance of Pt100-based devices. The five bars represent configurations commonly encountered in industrial sensors: Pt100 with PTFE housing, Pt100 with ceramic housing, PTFE-coated Pt100, PTFE-insulated assembly, and bare Pt100 element. Each bar conveys a synthetic approximation of measurement error in degrees Celsius at a reference temperature range. The values are illustrative and not official specifications; they are intended to demonstrate relative performance rather than absolute accuracy. Material choice affects thermal mass, heat transfer, chemical resistance, and long-term stability. PTFE housing provides chemical inertness and moderate thermal response; ceramic housing can improve response speed due to higher thermal conductivity but may be less resistant to aggressive chemicals. PTFE coatings reduce contamination and improve wetting properties but add thickness that can marginally slow heat transfer. Insulation minimizes ambient temperature influence but may increase response time due to added thermal mass. Bare Pt100 elements typically offer the fastest response and smallest packaging-related error, yet require careful protection from environmental exposure.

In practice, engineers and product teams use such comparisons to tailor sensor configurations to specific applications, balancing accuracy, response time, durability, and cost. This visualization helps translate material and assembly choices into tangible performance expectations, supporting smarter product development, clear customer guidance, and evidence-based supplier decisions. By highlighting how housing, coating, and insulation influence measurement outcomes, the chart encourages data-driven design optimization and clearer communication of sensor capabilities across varied industrial settings.

Top Selling Products