From a China-based manufacturer, I bring you our Pt100 Dual Element sensor assembly built for reliable, redundant temperature measurement in challenging process environments. Two independent Pt100 elements in a single housing give you cross-check capability and improved uptime, while the 4-wire configuration reduces lead resistance errors. This design suits industrial process control, food & beverage, pharmaceutical, and HVAC applications. We offer robust sheath options, corrosion-resistant alloys, and IP-rated protection to withstand harsh media. Being a China manufacturer, we provide competitive pricing, short lead times, and flexible OEM customization to meet your spec sheets and calibration standards, even IEC 60751. Each unit is tested before shipment, with traceable data to support QA requirements. If your team needs a dependable temp solution and you want to streamline supplier management, this Pt100 Dual Element is ready to integrate into your line. Reach out with your target quantities and we’ll tailor the package to your needs.
Across industries, Pt100 dual-element RTDs are trending for precision and resilience. A dual-element design houses two Pt100 sensors in one assembly, enabling redundancy and diagnostic capability. If one element drifts or fails, the other maintains measurement, reducing downtime and preventing costly excursions. With careful wiring and compensation, dual-element RTDs deliver stable, high-accuracy readings across wide ranges and harsh environments. Direct factory sourcing offers clear advantages for global buyers. You gain shorter lead times, consistent quality, and full traceability from material to final sensor. Customization options—sheath material, connection heads, calibration standards, and response time—can align with any process and controller. Rigorous testing and conformance to international standards support performance in critical applications, even in demanding conditions. In today’s supply chains, factory-direct excellence translates into reliable data, lower risk, and faster project timelines.
| Spec_ID | Location | Element | R0 (Ω) @ 0°C | Tolerance Class | Temp Range (°C) | Response Time (s) | Sheath Material | Outer Dia (mm) | Cable Length (m) | Calibration Status | Calibration Interval (months) | Notes |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PDT-01A | Plant North, Assembly Line 1 | A | 100.00 | Class A | -50 to 150 | 0.8 | Stainless Steel 316 | 2.0 | 2 | Calibrated | 12 | Thin-walled probe with fast response |
| PDT-01B | Plant North, Assembly Line 1 | B | 100.20 | Class A | -40 to 130 | 0.9 | Stainless Steel 316 | 2.2 | 3 | Certified | 12 | Dual-element pair for differential readings |
| PDT-02A | Plant East, Module 3 | A | 100.05 | Class B | -50 to 180 | 1.2 | Inconel 600 | 2.5 | 5 | Certified | 24 | High-temperature variant |
| PDT-02B | Plant East, Module 3 | B | 99.95 | Class B | -20 to 150 | 1.0 | Stainless Steel 316 | 2.0 | 10 | Calibrated | 12 | Redundancy-ready twin element |
| PDT-03A | Plant South, Line 2 | A | 100.10 | Class A | -60 to 200 | 0.7 | Stainless Steel 316L | 2.0 | 1.5 | Certified | 12 | Grade A traceability |
| PDT-03B | Plant South, Line 2 | B | 100.30 | Class B | -50 to 150 | 1.3 | Alloy 825 | 2.4 | 7 | Calibrated | 24 | Rugged, sealed junction |