Two-Color Level Gauge’s Clear Vision: The B69H-32-W Mica-Glass Gasket Assembly
At a power plant boiler site, noise meets steam. The operator stands at the two-color level gauge, needing only a glance at the red-and-green display to know the water level—steam phase is red, liquid phase is green, the boundary sharp and clear. This direct, reliable reading relies entirely on t...Read more -
The Turboset’s Eyes: Wiring Secrets for the HTACC-LT-606Z Displacement Sensor
The HTACC-LT-606Z Displacement Sensor is the “eye” monitoring rotor axial shift and shaft vibration. It changes tiny rotor movements into electric signals, which go to the monitoring system, triggering an alarm if values spike. Often, the sensor itself is fine. The issue is sloppy ele...Read more -
HC8900FKP26H Lubricating Oil Filter Element: A Successful Replacement in Thermal Power Plant
Many power plants using PALL lubricating oil filters have faced the same problem — the filters work well, but they’re expensive and take too long to arrive. When an urgent overhaul comes and there’s no stock, the unit must wait. One 300MW thermal power plant ran into this issue until they tried t...Read more -
Wind Power Guardian: Identifying a Qualified Hydraulic Filter Alternative 01.NR.1000.25VG.10.B.P
In a wind turbine generator, the gearbox is considered the core component, with replacement or repair costs often exceeding 30% of the entire unit’s value. The gearbox’s reliable operation is guarded by the hydraulic system and its filter element. Today, we discuss how to ensur...Read more -
16-Channel Relay Module 3500/33-01-00: Three Steps to Pinpoint the Problem from DCS Alarm
In the turbine monitoring system, the 3500/33-01-00 Relay Module acts as the “signal executor”. When the DCS (Distributed Control System) sends a command—like “Open Valve” or “Start Pump”—the module is responsible for transmitting the signal to the field device...Read more -
Rotor Eccentricity Sensor PR6423/002-030: Identifying EMI and Inspection Priorities
Steam turbine rotor eccentricity monitoring depends entirely on the PR6423/002-030 eddy current sensor. It captures the rotor’s eccentricity value in real time, issuing an alarm if the value exceeds tolerance to prevent shaft rubbing and bearing damage. However, power plant environments are...Read more -
Shaft Vibration Preamplifier TM301-A02-B01-C00-D00-E00-F00-G00 in High-Temperature and High-Humidity Environments
Accurate steam turbine shaft vibration measurement relies heavily on the eddy current proximity probe preamplifier TM301-A02-B01-C00-D00-E00-F00-G00. It acts as the “signal relay station,” amplifying and processing the shaft vibration signal collected by the probe before transmitting ...Read more -
Turbine MSV Position Sensor TD-1-800: Yields Comprehensive Benefits in Unit Safety and Efficiency
The high-pressure main steam valve (MSV) in a steam turbine is the “master gate” controlling the flow of boiler steam into the turbine. The precise degree to which this gate opens or closes relies entirely on the feedback signal from the LVDT linear position sensor. An accurate signal...Read more -
RJ-17.5-950 Bolt Heater + Control Cabinet: High-Efficiency and Safe Heating in Power Plants
In power plants, numerous large bolts are found on turbines and boilers. Dismantling or installing these bolts requires preheating—thermal expansion and contraction loosen the bolts, making them easy to turn. However, the heating process is complex: bolts of different materials and sizes require ...Read more -
AST Solenoid Valve Seat JZPK-003A: Design Logic for Anti-Erosion and Durable Sealing under High Pressure
The AST fire-resistant fluid solenoid valve is the “critical switch” of the turbine emergency trip system, and the valve seat JZPK-003A is the core contact surface of this switch. The fire-resistant fluid pressure in the AST system is high. Long-term, high-velocity fluid scouring aga...Read more -
Collaborative Roles of F3DG5S2-062A-220DC-50-DFZKV/B8 Isolation Valve, AST, and OPC Solenoid Valves in Emergency Trip System
Steam turbines operate at extremely high speeds. If a problem occurs and the unit fails to trip promptly, the consequences can range from minor bearing damage to catastrophic machine write-off. The Emergency Trip System (ETS) is the “life-saving” core of the turbine protection. Withi...Read more -
Turbine Overspeed Protection Solenoid Valve SV4-10-C-0-00: How Threaded Cartridge Design Outperforms Traditional Connections
Turbine overspeed is a critical concern in power generation. Once the rotational speed exceeds the upper limit, the consequences range from minor blade damage to catastrophic machine failure. Within the overspeed protection system, the solenoid valve acts as the “key executor.” The S...Read more