Detail of MM2XP Intermediate relays:
| Coil ratings | 24 VDC 87 mA |
| Contact form | DPDT |
| Contact method | Single |
| Contact material | Ag |
| Contact rated load | 110 VDC 7 A (Resistive load)110 VDC 6 A (Inductive load (L/R = 7 ms)) |
| Terminal structure | Plug-in terminal |
|
Degree of protection |
Closed type (cover) | |
|
Terminal structure |
Plug-in terminal | |
|
Coil |
Coil ratings |
24 VDC 87 mA |
|
Coil resistance |
275 Ω | |
|
Operate voltage (Set voltage) |
70% max. | |
|
Release voltage (Reset voltage) |
10% min. | |
|
Maximum voltage |
110% | |
|
Power consumption |
Approx. 2.1 W | |
|
Contact |
Contact rated load |
110 VDC 7 A (Resistive load)
110 VDC 6 A (Inductive load (L/R = 7 ms)) |
|
Max. contact voltage |
250 VAC/250 VDC | |
|
Max. contact current |
AC: 7.5 A/DC: 7.5 A | |
|
Maximum switching power |
20 VA/800 W (Resistive load)/660 W (Inductive load (L/R = 7 ms)) | |
|
Contact form |
DPDT | |
|
Contact method |
Single | |
|
Contact material |
Ag | |
|
Contact resistance |
50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
|
Operating time |
50 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) |
|
Reset time |
30 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) |
|
Maximum operating frequency |
Mechanical: 7200 time/h
Rated load: 1800 time/h |
|
Vibration resistance (destruction) |
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
|
Vibration resistance (Malfunction) |
10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) |
|
Failure rate |
5 VDC 10 mA (failure level: Preference value, Switching frequency: 60 operations per minute) |
|
Ambient temperature (Operating) |
-10 to 55 ℃ (with no freezing or condensation) |
|
Ambient humidity (Operating) |
5 to 85% RH |
|
Weight |
Approx. 225 g |
|
Mounting method |
Socket |