I’m a China-based manufacturer, and I stand behind the {Current Transformer For Dc Measurement} that I've developed for precise DC current sensing in test benches, power supplies, and motor drives. This compact unit provides galvanic isolation, fast response, and linear DC measurement across a broad range, from a few amps to hundreds. It integrates easily with PLCs and data loggers, delivering clean signals that reduce noise in harsh industrial environments. Our design uses Hall-effect sensing, ensuring accurate DC measurement even in the presence of AC components, with low temperature drift and excellent long-term stability. I value reliability, cost-efficiency, and quick delivery, backed by full technical support and documentation. If you’re sourcing from a China Manufacturer, you’ll appreciate our standard certifications, RoHS compliance, and flexible MOQ. Tell me your voltage, current range, and connector preferences, and I’ll tailor the {Current Transformer For Dc Measurement} to your application.
Global buyers seeking DC measurement require current transformers that pair precision with robust construction. A DC-capable CT delivers stable ratio accuracy across ranges and fast transient response, enabling peak performance in energy storage, data centers, and industrial drives. Optimized cores, sealed housings, and high insulation ratings minimize stray effects and support safe operation in high-voltage DC systems. Rigorous testing and calibration traceability to international standards ensure reliable monitoring over time. Behind peak performance is service backed by deep expertise: customization of ratios and form factors, global logistics, and scalable supply to meet project timelines. From design qualification to on-site commissioning and field support, a capable partner reduces risk, minimizes downtime, and extends device life. Clear documentation, warranty coverage, and timely technical assistance help buyers deploy DC measurement with confidence across regions.
| Model | Primary Current Range (A) | DC Measurement Range (A) | Accuracy (±%) | Burden (VA) | Response Time (ms) | Temperature Range (°C) | Calibration Date | Service Window (years) |
|---|---|---|---|---|---|---|---|---|
| CT-DC-101 | 50 - 1000 | 0 - 1000 | 0.25 | 2.5 | 5 | -20 to 85 | 2024-11-18 | 10 |
| CT-DC-102 | 30 - 800 | 0 - 800 | 0.30 | 1.8 | 4 | -25 to 85 | 2023-04-12 | 8 |
| CT-DC-201 | 100 - 2000 | 0 - 1500 | 0.20 | 3.2 | 6 | -10 to 90 | 2025-02-01 | 12 |
| CT-DC-202 | 200 - 3200 | 0 - 3200 | 0.15 | 5.0 | 8 | -20 to 95 | 2026-03-08 | 15 |
| CT-DC-301 | 25 - 500 | 0 - 500 | 0.35 | 1.2 | 3 | -30 to 75 | 2022-09-30 | 6 |
| CT-DC-302 | 75 - 1200 | 0 - 1000 | 0.25 | 2.0 | 4.5 | -15 to 85 | 2024-07-21 | 9 |
| CT-DC-999 | 10 - 400 | 0 - 400 | 0.50 | 0.9 | 2.5 | -40 to 70 | 2021-12-05 | 5 |